OverCurrentPSFault TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT Overcurrent Output current has exceeded internal fault limit. Output current has exceeded internal fault limit Output current has exceeded internal fault limit. - Check motor load. - Check acceleration times in parameter group 23 Speed reference ramp. - Check motor and motor cable (including phasing and delta/star connection). - Check that the start-up data in parameter group 99 corresponds to the motor rating plate. - Check that there are no power factor correction capacitors or surge absorbers in motor cable. - Check encoder cable (including phasing). Output current has exceeded internal fault limit. Check: - motor load - acceleration times - motor and motor cable - start-up data (group 99) - there are no power factor correction capacitors in motor cable - encoder cable. OvervoltagePSFault TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT DC link overvoltage DC link overvoltage fault DC link overvoltage fault Excessive intermediate circuit DC voltage. -Check that overvoltage control is on (parameter 30.30 Overvoltage control). -Check that the supply voltage matches the nominal input voltage of the drive. -Check the supply line for static or transient overvoltage. -Check brake chopper and resistor (if present). -Check deceleration time. -Use coast-to-stop function (if applicable). -Retrofit drive with brake chopper and brake resistor. DC link overvoltage Check -30.30 Overvoltage control -supply voltage matches drive nominal input voltage -supply line for static or transient overvoltage -chopper/resistor -decel. time Coast-to-stop. Retrofit drive with chopper and resistor. ShortCircuitPSFault TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT Short circuit Short-circuit in motor cable(s) or motor. Short-circuit in motor cable(s) or motor Short-circuit in motor cable(s) or motor. - Check motor and motor cable. - Check there are no power factor correction capacitors or surge absorbers in motor cable. Short-circuit in motor cable(s) or motor. - Check motor and motor cable. - Check there are no power factor correction capacitors or surge absorbers in motor cable. UndervoltagePSFault TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT DC link undervoltage DC link undervoltage fault DC link undervoltage fault Intermediate circuit DC voltage is not sufficient because of a missing supply phase, blown fuse or fault in the rectifier bridge. -Check supply cabling, fuses and switchgear. Intermediate circuit DC voltage is not sufficient because of a missing supply phase, blown fuse or fault in the rectifier bridge. -Check supply cabling, fuses and switchgear. EarthPSFault TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT Earth leakage Earth leakage fault Earth leakage fault Load unbalance in eg, motor or motor cable Check -no power factor correction capacitors or surge absorbers in cable -no earth fault in motor or cables: measure insulation resistances If no earth fault detected, contact ABB. Load unbalance in eg, motor or motor cable Check -no power factor correction capacitors or surge absorbers in cable -no earth fault in motor or cables: measure insulation resistances If no earth fault detected, contact ABB. RedundantMeasurementPSFault TUCOS_PSL2_DRIVER_Events Redundant measurement Redundant measurement Redundant measurement Redundant measurement supervision has indicated a difference in the duplicated measurements that is outside the limits. - Contact your local ABB representative. Redundant measurement supervision has indicated a difference in the duplicated measurements that is outside the limits. - Contact your local ABB representative. Redundant measurement supervision has indicated a difference in the duplicated measurements that is outside the limits. (Solar applications) IGBT_Overtemp_Fault TUCTC_TUCLC_common_Events IGBT overtemperature Estimated drive IGBT temperature is excessive. Estimated drive IGBT temperature is excessive Estimated drive IGBT temperature is excessive. - Check ambient conditions. - Check air flow and fan operation. - Check heatsink fins for dust pick-up. - Check motor power against drive power. Estimated drive IGBT temperature is excessive. - Check ambient conditions. - Check air flow and fan operation. - Check heatsink fins for dust pick-up. - Check motor power against drive power. Too much current in off-line thermal model while thermal current limitation passivated. BcErPSFault TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT Brake resistor wiring Brake chopper wiring fault Brake chopper wiring fault Brake resistor short circuit or brake chopper control fault. -Check brake chopper and brake resistor connection. -Ensure brake resistor is not damaged. Brake resistor short circuit or brake chopper control fault. -Check brake chopper and brake resistor connection. -Ensure brake resistor is not damaged. BcScPSFault TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT BC short circuit Brake chopper short circuit Brake chopper short circuit Short circuit in brake chopper IGBT. - Ensure brake resistor is connected and not damaged. - Check the electrical specifications of the brake resistor against the Hardware manual. -Replace brake chopper (if replaceable). Short circuit in brake chopper IGBT. - Ensure brake resistor is connected and not damaged. - Check the electrical specifications of the brake resistor against the Hardware manual. -Replace brake chopper (if replaceable). BcIgbtOvertempFault TUCTC_TUCLC_common_Events BC IGBT excess temperature Excessive brake chopper IGBT temperature Excessive brake chopper IGBT temperature Brake chopper IGBT temperature has exceeded internal fault limit. - Let chopper cool down. - Check for excessive ambient temperature. - Check for cooling fan failure. - Check for obstructions in the air flow. - Check the dimensioning and cooling of the cabinet. - Check resistor overload protection function settings (parameter group 43 Brake chopper). - Check that braking cycle meets allowed limits. - Check that drive supply AC voltage is not excessive. Brake chopper IGBT temperature has exceeded internal fault limit. - Let chopper cool down. - Check: for excessive ambient temperature, cooling fan, resistor overload protection function settings, braking duty cycle, drive supply AC voltage. BC IGBT thermal mode fault. BrOvertempFault TUCTC_TUCLC_common_Events BR excess temperature Excessive brake resistor temperature Excessive brake resistor temperature Brake resistor temperature has exceeded fault limit defined by parameter 43.11 Brake resistor fault limit. - Stop drive. Let resistor cool down. - Check resistor overload protection function settings (parameter group 43 Brake chopper). - Check fault limit setting, parameter 43.11 Brake resistor fault limit. - Check that braking cycle meets allowed limits. Brake resistor temperature has exceeded fault limit defined by parameter 43.11 Brake resistor fault limit. - Stop drive. Let resistor cool down. - Check parameter group 43 Brake chopper. - Check that braking cycle meets allowed limits. Braking resistor thermal model fault TempSensorFault TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT Measurement circuit temperature Problem with internal temperature measurement of the drive. If the device has only one IGBT temperature measurement in one phase, the fault is generated, otherwise warning. Problem with internal temperature measurement of the drive Problem with internal temperature measurement of the drive. - Contact your local ABB representative. Problem with internal temperature measurement of the drive. - Contact your local ABB representative. CrossConFault TUCTC_Events Wiring or earth fault Incorrect input power and motor cable connection Incorrect input power and motor cable connection Incorrect input power and motor cable connection (i.e. input power cable is connected to drive motor connection). - Check input power connections. Incorrect input power and motor cable connection (i.e. input power cable is connected to drive motor connection). - Check input power connections. AC supply connected to outputs. InputPhaseLossFault TUCTC_Events Input phase loss Intermediate circuit DC voltage is oscillating. Intermediate circuit DC voltage is oscillating Intermediate circuit DC voltage is oscillating due to missing input power line phase or blown fuse. - Check input power line fuses. - Check for input power supply imbalance. Intermediate circuit DC voltage is oscillating due to missing input power line phase or blown fuse. - Check input power line fuses. - Check for input power supply imbalance. Too much ripple in th Udc due to missing supply phase. OutputPhaseLossFault TUCTC_Events Output phase loss Missing motor connection Missing motor connection Motor circuit fault due to missing motor connection (all three phases are not connected). - Connect motor cable. Motor circuit fault due to missing motor connection (all three phases are not connected). - Connect motor cable. Output phase loss detected. IDRunFault TUCTC_Events ID run Motor ID run failed. Motor ID run failed Motor ID run was not completed successfully. - Check the event log for an auxiliary code. See appropriate actions for each aux. code below. Aux code = 1: Current limit is too low. Aux code = 2: Maximum speed and/or field weakening point is too low. Aux code = 3: Maximum torque is too low. Aux code = 4: Current measurement calibration error. Aux code = 5…8: Inductance estimation error. Aux code = 9: Asynchronous motor acceleration error. Aux code = 10: Asynchronous motor deceleration error. Aux code = 11: Asynchronous motors speed dropped to zero. Aux code = 12: PM motor acceleration error 1. Aux code = 13: PM motor acceleration error 2. Aux code = 14…16: PM motor speed dropped to zero. Aux code = 17: SynRM pulse test error Aux code = 18: Too big motor for advanced standstill ID run Aux code = 19: Asynchronous motor data error Motor ID run was not completed successfully. - Check the event log for an auxiliary code. See appropriate actions for each aux code in the manual. ID run failure. CalibrationFault TUCTC_Events Calibration Current measurement calibration fault Current measurement calibration fault Measured offset of output phase current measurement or difference between output phase U2 and W2 current measurement is too great (the values are updated during current calibration). - Try performing the current calibration again (select Current measurement calibration at parameter 99.13). If the fault persists, contact your local ABB representative. Measured offset of output phase current measurement or difference between output phase current measurement is too great. - Try performing the current calibration again. If the fault persists, contact your local ABB representative. Current measurement offset or gain error is too big. AutophasingFault TUCTC_Events Autophasing Autophasing routine has failed. Autophasing routine has failed. Autophasing routine has failed. - Try other autophasing modes (see parameter 21.13 Autophasing mode) if possible. Autophasing routine has failed. - Try other autophasing modes (see parameter 21.13 Autophasing mode) if possible. PMSM initial angle search failed or too big motor model error in closed loop. LinkErrPSFault TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT PU communication Communication errors detected between the drive control unit and the power unit. Communication errors detected between the drive control unit and the power unit Communication errors detected between the drive control unit and the power unit. - Check the connection between the drive control unit and the power unit. Communication errors detected between the drive control unit and the power unit. - Check the connection between the drive control unit and the power unit. OverTemp3LFault TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT Overtemperature hw Hardware overtemperature detection (3L target specific) ExternalFault TUREL_FA_STUB_Events External External fault triggered either from - digital input 3 or - by setting g_u16TestNewFault = 1 or - error in the charge relay control AUX_EXTERNAL_FAULT_TEST AUX_CHARGE_RELAY_FAILED STOFault TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT Safe torque off Safe torque off function is active. Safe torque off function is active Safe torque off function is active, i.e. safety circuit signal(s) connected to connector XSTO is broken during start, or while drive is stopped and parameter 31.22 STO diagnostics is set to Fault. - Check safety circuit connections. For more information, see appropriate drive hardware manual. Safe torque off function is active, i.e. safety circuit signal(s) connected to connector XSTO is broken during start, or while drive is stopped and parameter 31.22 STO diagnostics is set to Fault. - Check safety circuit connections. ehndl_IncompatibleOptionModuleFlt Option_module Incompatible option module Option module not supported Option module not supported Remove incompatible option module. Incompatible option module in FBA A Incompatible option module in FBA B IGBTOverLoadFault TUCTC_TUCLC_common_Events IGBT overload Excessive IGBT junction to case temperature Excessive IGBT junction to case temperature Excessive IGBT junction to case temperature. This fault protects the IGBT(s) and can be activated by a short circuit in the motor cable. - Check motor cable. Excessive IGBT junction to case temperature. This fault protects the IGBT(s) and can be activated by a short circuit in the motor cable. - Check motor cable. dTjc fault IGBTTempFault TUCTC_TUCLC_common_Events IGBT temperature Drive IGBT temperature is excessive. Drive IGBT temperature is excessive Drive IGBT temperature is excessive. - Check ambient conditions. - Check air flow and fan operation. - Check heatsink fins for dust pick-up. - Check motor power against drive power. Drive IGBT temperature is excessive. - Check ambient conditions. - Check air flow and fan operation. - Check heatsink fins for dust pick-up. - Check motor power against drive power. Tj fault limit exceeded. CoolingFault TUCTC_TUCLC_common_Events Cooling Drive module temperature is excessive. Drive module temperature is excessive Drive module temperature is excessive. - Check ambient temperature. If it exceeds 40 °C (104 °F), ensure that load current does not exceed derated load capacity of drive. See appropriate Hardware Manual. - Check drive module cooling air flow and fan operation. - Check inside of cabinet and heatsink of drive module for dust pick-up. Clean whenever necessary. Drive module temperature is excessive. - Check ambient temperature. See appropriate Hardware Manual. - Check cooling air flow and fan operation. - Check heatsink of drive module for dust pick-up. Clean whenever necessary. On-line thermal model, cooling diagnostics, fault. DCunbalanceFault TUCTC_Events DC unbalance fault DC unbalance fault. DC unbalance of 3-level devices. ADCErrorPSFault TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT Measurement circuit ADC Measurement circuit fault Measurement circuit fault Measurement circuit fault. - Contact your local ABB representative. Measurement circuit fault. - Contact your local ABB representative. PCB_SpaceCoolingFault TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT PCB space cooling PCB space cooling fault PCB space cooling fault Check cooling fan inside the PCB space. Temperature difference between ambient and drive module PCB space temperature difference has exceeded fault limit. -Check cooling fan inside the PCB space. Temperature difference between ambient and drive module PCB space temperature difference has exceeded fault limit. Temperature difference between ambient and drive module PCB space temperature difference has exceeded fault limit. Check cooling fan inside the PCB space. ehndl_CuLogicError TUCOS_GENERAL_Events CU logic error Control unit's FPGA has lost its configuration. This fault cannot be reset. CU logic error This fault automatically reboots the control unit after a short delay. Control unit's FPGA has lost its configuration. This fault cannot be reset. This fault automatically reboots the control unit after a short delay. Control unit's FPGA has lost its configuration. This fault cannot be reset. Problem in the Control Unit hardware. Replace the Control Unit. SSW_InternalFault TUCOS_GENERAL_Events EVNT_SEP_AUX_FLT Internal SSW fault Internal SSW fault. This fault cannot be reset. This fault requires a reboot of the control unit either by switching the power off and on, or using parameter 98.06 Control board boot. Internal SSW fault is generated, if a fatal error occurrs in power-up phase of System Software (SSW). The SSW will run in a mode where only partial functionality is available. It is still possible to download new software with a loading package. Internal SSW fault is generated, if a fatal error occurrs in the SSW power-up phase. The system will run in SSW_FAULT-mode where only partial functionality is available. In this mode it is possible to download new SW with a loading package. Failure when starting the OS time tick. Failure when creating system tasks. Failure when initializing the file system. Failure when checking the file system. Failure when initializing the WoRm volumes. Failure when loading the FPGA configuration. Failure when loading the application program. TaskOverloadFault TUCOS_GENERAL_Events Task overload Task overload fault. This fault cannot be reset. Task overload fault Internal fault. Note: This fault cannot be reset. -Contact your local ABB representative. This fault requires a reboot of the control unit either by switching the power off and on, or using parameter 98.06 Control board boot. Internal fault. Note: This fault cannot be reset. -Contact your local ABB representative. Task overloaded. The execution of the task takes too long time. KernelEventFault TUCOS_GENERAL_Events Kernel overload Kernel overload fault. This fault cannot be reset. Kernel overload fault Operating system error. Note: This fault cannot be reset. -Contact your local ABB representative. This fault requires a reboot of the control unit either by switching the power off and on, or using parameter 98.06 Control board boot. Operating system error. Note: This fault cannot be reset. -Contact your local ABB representative. Operating system error. StackFault TUCOS_GENERAL_Events Stack overflow Stack overflow fault. This fault cannot be reset. Stack overflow fault Internal fault. Note: This fault cannot be reset. -Contact your local ABB representative. This fault requires a reboot of the control unit either by switching the power off and on, or using parameter 98.06 Control board boot. Internal fault. Note: This fault cannot be reset. -Contact your local ABB representative. Stack overflow fault FPGAVerIncompatible TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT FPGA version incompatible Firmware and FPGA are not compatible. Firmware and FPGA are not compatible. Update FPGA Firmware and FPGA versions are incompatible with each other. ehndl_InternalSWFlt2 DRIVE_LOGIC Internal SW error 2 Internal SW error Internal SW error Internal SW error Internal SW error Internal SW error EFBSerial1ErrFault TUCOS_EFB_Events EFB comm loss The EFB has detected a comm loss. Check communications with system. EFB comm loss fault The embedded fieldbus (EFB) interface has detected a comm loss. Please check communications with master / PLC / supervisory controller. See parameters 58.07, 58.08, and 58.09 to adjust settings. The embedded fieldbus (EFB) interface has detected a comm loss. Please check communications with master / PLC / supervisory controller. See parameters 58.07, 58.08, and 58.09 to adjust settings. EFBConfigFileFault TUCOS_EFB_Events EFB config file EFB protocol was unable to access its config file. EFB config file fault EFB protocol was unable to access its config file. Reload firmware or replace the unit. EFB protocol was unable to access its config file. Reload firmware or replace the unit. Embedded fieldbus configuration file fault. EFBForceTripFault TUCOS_EFB_Events EFB force trip This fault is not currently used at this time. EFB force trip This fault is not currently used at this time. This fault is not currently used at this time. EFBFault1 TUCOS_EFB_Events EFB load fault Unable to load protocol firmware or version mismatch between protocol and system firmware. EFB load fault Unable to load protocol firmware or version mismatch between protocol and system firmware. Reload firmware or replace the unit. Unable to load protocol firmware or version mismatch between protocol and system firmware. Reload firmware or replace the unit. EFBFault2 TUCOS_EFB_Events EFB fault 2 This fault is not currently used at this time. EFB fault 2 This fault is not currently used at this time. This fault is not currently used at this time. EFBFault3 TUCOS_EFB_Events EFB fault 3 This fault is not currently used at this time. EFB fault 3 This fault is not currently used at this time. This fault is not currently used at this time. UffLoadFault TUCOS_GENERAL_Events Internal file load Internal file load fault. This fault cannot be reset. Internal file load fault File read error. Note: This fault cannot be reset. -Contact your local ABB representative. This fault requires a reboot of the control unit either by switching the power off and on, or using parameter 98.06 Control board boot. File read error. Note: This fault cannot be reset. -Contact your local ABB representative. Loading of an UFF file has failed. The aux code tells which UFF file is in question. Permanent fault. UffLoadNotPermanentFault TUCOS_GENERAL_Events Internal record load Internal record load fault Internal record load fault Internal record load error. -Contact your local ABB representative. Internal record load error. -Contact your local ABB representative. Loading of a UFF record has failed. This fault is used when a UFF loading fails but the activated fault can be resettable. UffLoadPuRatingIdFault TUCOS_GENERAL_Events Rating ID fault Rating ID fault Rating ID load error Rating ID load error. -Contact your local ABB representative. Rating ID load error. -Contact your local ABB representative. Loading of the Rating ID has failed. This fault is used when a UFF loading fails but the activated fault can be resettable. LicensingFault TUCOS_GENERAL_Events EVNT_SEP_AUX_FLT Licensing fault Licensing fault. This fault cannot be reset. A required license is missing. The software on this drive requires a license that couldn't be found. The missing license is indicated by the value of the aux code field. Please contact your product vendor for further instructions. This fault requires a reboot of the control unit either by switching the power off and on, or using parameter 98.06 Control board boot. A license that is required for the drive to function properly is missing. The missing license is Nxxxx, where xxxx is indicated by the 4-digit value of the aux code field. A required license is missing. A license that is required for the drive to function properly is missing. Record the aux codes of all active licensing faults and contact your product vendor for further instructions. ApplLoadingFault TUCAC_Events Application loading Loading of the CoDeSys application has failed. Fault indicates that the application loading has failed. Causes for the failure can be problems in the content of the application UFF file or that the Codesys runtime-system initialization has failed. SynchronizationFault TUCLC_Events Synchronization fault Runaway current synchronization fault. IsolationFault TUCLC_Events Isolation fault Isolation fault. Ground impedance is too small. ehndl_PowerUnitLogicDownloadHasFailed TUCOS_Power_Unit EVNT_SEP_AUX_FLT Power unit logic's download has failed Download of new logic configuration file to the PU has failed. New download can be started. A power-up is required to exit the download mode, but the PU's FPGA configuration could be corrupted and prevents drive's normal operation. Power unit logic's download has failed Download of new logic configuration file to the PU has failed. Drive is in a special mode. New download can be started. A power-up is required to exit the special mode, but the PU's FPGA configuration could be corrupted and prevents drive's normal operation. Download of new logic configuration file to the PU has failed. Drive is in a special mode. New download can be started. A power-up is required to exit the special mode, but the PU's FPGA configuration could be corrupted and prevents drive's normal operation. Download of new logic configuration file to the PU has failed. New download can be started. A power-up is required to exit the special mode, but the PU's FPGA configuration could be corrupted and prevents drive's normal operation. Error code ehndl_DriveRestartIsRequired TUCOS_Power_Unit Control unit restart is required New logic configuration file has been downloaded to the PU. Drive is in a special mode and a power-up is required to exit the download mode. Control unit restart is required New logic configuration file has been downloaded to the PU. Drive is in a special mode and a power-up is required to exit the download mode. New logic configuration file has been downloaded to the PU. Drive is in a special mode and a power-up is required to exit the download mode. New logic configuration file has been downloaded to the PU. Drive is in a special mode and a power-up is required to exit the download mode. PFPSFault TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT PU board powerfail Power unit power supply failure Power unit power supply failure Power unit power supply failure. - Contact your local ABB representative. Power unit power supply failure. Auxiliary power failure of power unit board DFFPSFault TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT Measurement circuit DFF Measurement circuit fault Measurement circuit fault Measurement circuit fault. - Contact your local ABB representative. Measurement circuit fault. - Contact your local ABB representative. PSL2DriverInternalFault TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT PU communication internal Internal communication error Internal communication error Internal communication error. - Contact your local ABB representative. Internal communication error. - Contact your local ABB representative. TempFault TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT Excess temperature Power unit module temperature is excessive. Power unit module temperature is excessive. Check ambient conditions. Check air flow and fan operation. Check heatsink fins for dust pick-up. Check motor power against drive power. Power unit module temperature is excessive. TempDifFault TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT Excess temperature difference High temperature difference between the IGBTs of different phases. High temperature difference between the IGBTs of different phases. Check the motor cabling. Check cooling of drive module(s). Too high temperature difference between the highest and lowest measured IGBT temperatures of different phases. The amount of available temperatures depends on the frame size. BRResistorFault TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT Brake resistor Brake chopper power lower than required Brake chopper power lower than required Brake resistor broken or not connected. -Check that a brake resistor has been connected. -Check the condition of the brake resistor. -Check the dimensioning of the brake resistor. Brake resistor broken or not connected. -Check that a brake resistor has been connected. -Check the condition of the brake resistor. -Check the dimensioning of the brake resistor. BUEFFault TUCOS_BU_Events BU earth leakage Earth fault detected by the branching unit: sum of all currents is exceeding the level. BUIDiffFault TUCOS_BU_Events EVNT_SEP_AUX_FLT BU current difference Branching unit difference check fault for currents BUUCDiffFault TUCOS_BU_Events EVNT_SEP_AUX_FLT BU DC link difference DC voltage difference fault DC voltage difference fault Difference in DC voltages between parallel-connected inverter modules. -Contact your local ABB representative. Difference in DC voltages between parallel-connected inverter modules. -Contact your local ABB representative. Difference check fault for DC-link voltage BUCDDiffFault TUCOS_BU_Events EVNT_SEP_AUX_FLT BU commutation difference Branching unit difference check fault for CDX and CDY. BUUmainDiffFault TUCOS_BU_Events EVNT_SEP_AUX_FLT BU voltage difference Main voltage difference fault Main voltage difference fault Difference in main voltages between parallel-connected inverter modules. -Contact your local ABB representative. Difference in main voltages between parallel-connected inverter modules. -Contact your local ABB representative. Difference check fault for main voltage HWConfigFault TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT PU communication configuration PU channel configuration is not matching with the setting Configuration failure of power unit communication channel(s): channel information is not matching with parameters or channels are cross connected. Erroneous configuration of PU communication channel(s): the actual channel ids are not matching with parameters or channels are cross connected. ReducedRunPSFault TUCOS_PSL2_DRIVER_Events Reduced run Some xINTs are missing Some of the configured power units are not found. The reduced run is possible if configured. Not all power units found, reduced run is possible FPGAErrPSFault TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT PU logic error power unit logic memory error The memory of the power unit logic is cleared. PU FPGA logic has lost its memory, signature register value is missing MemUnitDetached TUCOS_GENERAL_Events EVNT_SEP_AUX_FLT Memory Unit Detached Memory unit detached. This fault cannot be reset. This fault requires a reboot of the control unit either by switching the power off and on, or using parameter 98.06 Control board boot. Memory unit has been removed while the power is on. Memory Unit has been removed. Live removing or inserting of the memory unit is not supported. STSVPSFault TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT PU state feedback PU state feedback PU state feedback State feedback supervision supervises the state feedback signals from the output phases and compares the signals to the actual control signals. All of the output phases are sampled invidually. State feedback supervision supervises the state feedback signals from the output phases and compares the signals to the actual control signals. All of the output phases are sampled invidually. State feedback supervision supervises the state feedback signals from the output phases and compares the signals to the actual control signals. All of the output phases are sampled invidually. CHGFault TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT Charging feedback Charging feedback missing The charging feedback is missing. Formerly INVD UnknownPUFault TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_FLT Unknown PU fault Unknown power unit fault Unknown power unit fault The power unit logic has generated a fault which is not known by the softaware. -Check the logic and software compatility. The power unit logic has generated a fault which is not known by the softaware. -Check the logic and software compatility. DiagnosticsFault TUCTC_Events Diagnostics Diagnostics failed. INU or motor diagnostics failure. OverFrequencyFault TUCTC_Events Overfrequency Output frequency too high. Output frequency too high. Output frequency too high. Output frequency too high. Absolute output frequency has exceeded internal fault limit. LangDataRAMTableFault TUCOS_LANG_EXT_Events Text data overflow Language data table size is too short. Please, contact ABB. Language data table fault The buffer size is too short for language data, which are tried to locate into the drive's RAM, for string-by-string search. Please, Contact ABB. The table size is too short for language data, which are tried to locate into the drive's RAM, for string-by-string search. Please, Contact ABB, if this fault is active. The fault can be reseted and drive can be used normally. RAM buffer size is too short for language data. Increase the buffer length in LANG_config.h file. Lang32BitRAMTableFault TUCOS_LANG_EXT_Events Text 32-bit table overflow 32 bit bointer table size is too short. Please, contact ABB. 32 bit pointer table fault 32 bit bointer table size is too short for text, which are tried to locate into the drive's RAM, for string-by-string search. Please, Contact ABB. 32 bit bointer table size is too short for text, which are tried to locate into the drive's RAM, for string-by-string search. Please, Contact ABB, if this fault is active. The fault can be reseted and drive can be used normally. RAM buffer size is too short for 32 bit poiters. Increase the buffer length in LANG_config.h file. Lang64BitRAMTableFault TUCOS_LANG_EXT_Events Text 64-bit table overflow 64 bit bointer table size is too short. Please, contact ABB. 64 bit pointer table fault 64 bit bointer table size is too short for text, which are tried to locate into the drive's RAM, for string-by-string search. Please, Contact ABB. 64 bit bointer table size is too short for text, which are tried to locate into the drive's RAM, for string-by-string search. Please, Contact ABB, if this fault is active. The fault can be reseted and drive can be used normally. RAM buffer size is too short for 64 bit poiters. Increase the buffer length in LANG_config.h file. LangSourceFileRAMTableFault TUCOS_LANG_EXT_Events Text file overflow The table size is too short for opening language file. Please, contact ABB. Language file open fault The buffer size is too short for opening language file. Please, Contact ABB. The table size is too short for opening language file. Please, Contact ABB, if this fault is active. The fault can be reseted and drive can be used normally. RAM buffer size is too short for opening language file. Increase the buffer length in LANG_config.h file. ParSysFault TUCOS_GENERAL_Events Parameter system Parameter system fault Parameter system fault Parameter load or save failed. -Try forcing a save using parameter 96.07 Param save. Retry. Parameter load or save failed. -Try forcing a save using parameter 96.07 Param save. Retry. Failure in the parameter system. Fix mentioned in User manual description available with TUREL101+ UserSetFault TUCOS_GENERAL_Events User Set Fault BackupRestoreTimeoutFault TUCOS_GENERAL_Events Backup/Restore Timeout Backup/Restore timeout BR timeout fault Check panel / PC-tool communication and if it is still in backup / restore state. Thrown during backup taking or restoring operation when a panel or PC-tool fails to communicate with the drive as part of backup taking or restoring operation. EFBParFBusNotPresentFault TUCOS_EFB_Events EFB invalid parameterization Invalid EFB configuration. Please check EFB parameters in group 58. EFB invalid parameterization Invalid EFB configuration. Please check EFB parameters in group 58 and verify they are consistent with the configured protocol. Invalid EFB configuration. Please check EFB parameters in group 58 and verify they are consistent with the configured protocol. Embedded fieldbus invalid parameterization ehndl_APFault1 AP_Program AP Fault 1 ehndl_APFault2 AP_Program AP Fault 2 ehndl_APFault3 AP_Program AP Fault 3 ehndl_APFault4 AP_Program AP Fault 4 ehndl_APFault5 AP_Program AP Fault 5 ehndl_AdaptiveProgram AP_Program Adaptive program Adaptive program file incompatible or corrupted. Adaptive program file incompatible or corrupted. Adaptive program file incompatible or corrupted. Check the fault logger for a fault code extension. Adaptive program has faulted. Check the fault code extension for further information. Harmonized fault code: 0x64A6 Adaptive program fault. Adaptive program file incompatible or corrupted. Adaptive program file incompatible or corrupted. Check the fault logger for a fault code extension. ehndl_Standby_timeout NomValues Standby timeout Autostart delay elapsed. After autorestart delay is elapsed and drive can not be started this fault is given instead of Undervoltage. FaultReset TUCOS_GENERAL_Events Fault reset This event indicates that fault has been reset. The cause of the fault no longer exists and the fault reset has been requested and completed. Fault reset has been requested and done. OverCurrentWarning TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_WRNG Overcurrent Output current has exceeded internal fault limit. Output current has exceeded internal fault limit Output current has exceeded internal fault limit. - Check motor load. - Check acceleration times in parameter group 23 Speed reference ramp. - Check motor and motor cable (including phasing and delta/star connection). - Check that the start-up data in parameter group 99 corresponds to the motor rating plate. - Check that there are no power factor correction capacitors or surge absorbers in motor cable. - Check encoder cable (including phasing). Output current has exceeded internal fault limit. Check: - motor load - acceleration times - motor and motor cabl - start-up data in parameter group 99 - there are no power factor correction capacitor - encoder cable. OvervoltageWarning TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_WRNG DC link overvoltage DC link overvoltage warning DC link overvoltage warning Excessive intermediate circuit DC voltage -Check that overvoltage controller is on, parameter 30.30 Overvoltage control. -Check mains for static or transient overvoltage. -Check brake chopper and resistor (if used). -Check deceleration time. -Use coast-to-stop function (if applicable). -Retrofit frequency converter with brake chopper and brake resistor. Excessive intermediate circuit DC voltage Check -p. 30.30 Overvoltage control -mains for static or transient overvoltage -brake chopper/resistor -decel. time Use coast-to-stop. Retrofit drive with chopper and resistor. STOWarning TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_WRNG Safe torque off Safe torque off function is active. Safe torque off function is active Safe torque off function is active, i.e. safety circuit signal(s) connected to connector XSTO is broken during start, or while drive is stopped and parameter 31.22 STO diagnostics is set to Fault. - Check safety circuit connections. For more information, see appropriate drive hardware manual. Safe torque off function is active, i.e. safety circuit signal(s) connected to connector XSTO is broken during start, or while drive is stopped and parameter 31.22 STO diagnostics is set to Fault. - Check safety circuit connections. ShortCircuitWarning TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_WRNG Short circuit Short-circuit in motor cable(s) or motor. Short-circuit in motor cable(s) or motor Short-circuit in motor cable(s) or motor. - Check motor and motor cable. - Check there are no power factor correction capacitors or surge absorbers in motor cable. Short-circuit in motor cable(s) or motor. - Check motor and motor cable. - Check there are no power factor correction capacitors or surge absorbers in motor cable. UndervoltageWarning TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_WRNG DC link undervoltage DC link undervoltage warning DC link undervoltage warning Intermediate circuit DC voltage is not sufficient due to missing mains phase, blown fuse or rectifier bridge internal fault. -Check supply and fuses. Intermediate circuit DC voltage is not sufficient due to missing mains phase, blown fuse or rectifier bridge internal fault. -Check supply and fuses. EarthWarning TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_WRNG Earth leakage Earth leakage warning Earth leakage warning Load unbalance in eg, motor or cable Check -no power factor correction capacitors or surge absorbers -no earth fault in cables: measure insulation resistances If no earth fault detected, contact ABB. Load unbalance in eg, motor or cable Check -no power factor correction capacitors or surge absorbers -no earth fault in cables: measure insulation resistances If no earth fault detected, contact ABB. BcErWarning TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_WRNG Brake resistor wiring Brake resistor wiring warning Brake resistor wiring warning Brake resistor short circuit or brake chopper control fault. -Check brake chopper and brake resistor connection. -Ensure brake resistor is not damaged. Brake resistor short circuit or brake chopper control fault. -Check brake chopper and brake resistor connection. -Ensure brake resistor is not damaged. BcScWarning TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_WRNG BC short circuit Brake chopper short circuit Brake chopper short circuit Short circuit in brake chopper IGBT. -Replace brake chopper. -Ensure brake resistor is connected and not damaged. Short circuit in brake chopper IGBT. -Replace brake chopper. -Ensure brake resistor is connected and not damaged. BrOvertempAlarm TUCTC_TUCLC_common_Events BR excess temperature Excessive brake resistor temperature Excessive brake resistor temperature Brake resistor temperature has exceeded warning limit defined by parameter 43.12 Brake resistor warning limit. - Stop drive. Let resistor cool down. - Check resistor overload protection function settings (parameter group 43 Brake chopper). - Check parameter 43.12 Brake resistor warning limit. - Check that braking cycle meets allowed limits. Brake resistor temperature has exceeded warning limit defined by parameter 43.12 Brake resistor warning limit. - Stop drive. Let resistor cool down. - Check parameter group 43 Brake chopper. - Check that braking cycle meets allowed limits. Braking resistor thermal model alarm. BcIgbtOvertempAlarm TUCTC_TUCLC_common_Events BC IGBT excess temperature Excessive brake chopper IGBT temperature Excessive brake chopper IGBT temperature Brake chopper IGBT temperature has exceeded internal fault limit. - Let chopper cool down. - Check for excessive ambient temperature. - Check for cooling fan failure.Check for obstructions in the air flow. - Check the dimensioning and cooling of the cabinet. - Check resistor overload protection function settings (parameters 43.06…43.10). - Check that braking cycle meets allowed limits. - Check that drive supply AC voltage is not excessive. Brake chopper IGBT temperature has exceeded internal fault limit. - Let chopper cool down. - Check: for excessive ambient temperature, cooling fan, resistor overload protection function settings, braking duty cycle, drive supply AC voltage. BC IGBT thermal model warning BrDataAlarm TUCTC_TUCLC_common_Events EVNT_SEP_AUX_WRNG BR data Incorrect braking resistor data. Incorrect braking resistor data Incorrect braking resistor data. Aux code = 1: The braking resistor resistance value is too low. - Check that braking resistor resistance is sufficient. Aux code = 2: The thermal protection of braking resistor is enabled but braking resistor thermal time constant is is not given. - Check that braking resistor thermal time constant is given. Aux code = 3: The thermal protection of braking resistor is enabled but braking resistor maximum power is is not given. - Check that braking resistor maximum power is given. The braking resistor value is too low - Check that braking resistor resistance is sufficient. The thermal protection of braking resistor is enabled but data is not given - Check that braking resistor thermal time constant and maximum power are given. Braking resistor data is invalid (either too small resistor or thermal protection data not given altough thermal protection is enabled). R Br too low Br Tau Th not given Br P Max not given IGBT_OvertempAlarm TUCTC_TUCLC_common_Events IGBT overtemperature Estimated drive IGBT temperature is excessive. Estimated drive IGBT temperature is excessive Estimated drive IGBT temperature is excessive. - Check ambient conditions. - Check air flow and fan operation. - Check heatsink fins for dust pick-up. - Check motor power against drive power. Estimated drive IGBT temperature is excessive. - Check ambient conditions. - Check air flow and fan operation. - Check heatsink fins for dust pick-up. - Check motor power against drive power. Too much current in off-line thermal model while thermal current limitation passivated. NoMotDataAlarm TUCTC_Events No motor data Parameters in group 99 have not been set. Parameters in group 99 have not been set Parameters in group 99 have not been set. - Check that all the required parameters in group 99 have been set. Note: It is normal for this warning to appear during the start-up until the motor data is entered. Parameters in group 99 have not been set. - Check that all the required parameters in group 99 have been set. Note: It is normal for this warning to appear during the start-up until the motor data is entered. MotorNomValueAlarm TUCTC_Events Motor nominal value Incorrect motor parameter values, or wrong drive dimensioning Incorrect motor parameter values, or wrong drive dimensioning The motor parameters are set incorrectly. - Check the settings of the motor configuration parameters in group 99. The drive is not dimensioned correctly. - Check that the drive is sized correctly for the motor. The motor parameters are set incorrectly. - Check the settings of the motor configuration parameters in group 99. The drive is not dimensioned correctly. - Check that the drive is sized correctly for the motor. Motor data not given or motor/inu ratio not acceptable. Motor slip frequency is too small Too big error between synch. and nominal speed Motor nom speed is higher than synch with p=1 Motor nom current is not within allowed limits Motor nom voltage is not within allowed limits Motor nom power is higher than apparent power Nom power not consistent with nom speed&torque IGBTOverLoadAlarm TUCTC_TUCLC_common_Events IGBT overload Excessive IGBT junction to case temperature Excessive IGBT junction to case temperature Excessive IGBT junction to case temperature. This warning protects the IGBT(s) and can be activated by a short circuit in the motor cable. - Check motor cable. Excessive IGBT junction to case temperature. This warning protects the IGBT(s) and can be activated by a short circuit in the motor cable. - Check motor cable. dTjc warning IGBTTempAlarm TUCTC_TUCLC_common_Events IGBT temperature Drive IGBT temperature is excessive. Drive IGBT temperature is excessive Drive IGBT temperature is excessive. - Check ambient conditions. - Check air flow and fan operation. - Check heatsink fins for dust pick-up. - Check motor power against drive power. Drive IGBT temperature is excessive. - Check ambient conditions. - Check air flow and fan operation. - Check heatsink fins for dust pick-up. - Check motor power against drive power. Tj has exceeded alarm limit CoolingAlarm TUCTC_TUCLC_common_Events Cooling Drive module temperature is excessive. Drive module temperature is excessive Drive module temperature is excessive. - Check ambient temperature. If it exceeds 40 °C (104 °F), ensure that load current does not exceed derated load capacity of drive. See appropriate Hardware Manual. - Check drive module cooling air flow and fan operation. - Check inside of cabinet and heatsink of drive module for dust pick-up. Clean whenever necessary. Drive module temperature is excessive. - Check ambient temperature. See appropriate Hardware Manual. - Check cooling air flow and fan operation. - Check heatsink of drive module for dust pick-up. Clean whenever necessary. On-line thermal model, cooling diagnostics alarm. ADCErrorWarning TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_WRNG Measurement circuit ADC Measurement circuit fault Measurement circuit fault Measurement circuit fault. - Contact your local ABB representative. Measurement circuit fault. - Contact your local ABB representative. PCB_SpaceCoolingWarning TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_WRNG PCB space cooling PCB space cooling warning PCB space cooling warning Check cooling fan inside the PCB space. Temperature difference between ambient and drive module PCB space temperature difference has exceeded warning limit. -Check cooling fan inside the PCB space. Temperature difference between ambient and drive module PCB space temperature difference has exceeded warning limit. Temperature difference between ambient and drive module PCB space temperature difference has exceeded warning limit. Check cooling fan inside the PCB space. ehndl_PowerUnitLogicUpdateInProgress TUCOS_Power_Unit Power unit's logic update in progress New logic configuration file is downloaded to the PU. Drive is in a special mode and can not be started. Power unit's logic update in progress New logic configuration file is downloaded to the PU. Drive is in a special mode and can not be started. New logic configuration file is downloaded to the PU. Drive is in a special mode and can not be started. New logic configuration file is downloaded to the PU. Drive is in a special mode and can not be started. PFWarning TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_WRNG PU board powerfail Power unit power supply failure Power unit power supply failure Power unit power supply failure. - Contact your local ABB representative. Power unit power supply failure. - Contact your local ABB representative. DFFWarning TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_WRNG Measurement circuit DFF Measurement circuit fault Measurement circuit fault Measurement circuit fault. - Contact your local ABB representative. Measurement circuit fault. - Contact your local ABB representative. PSL2DriverInternalWarning TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_WRNG PU communication internal Communication errors detected between the drive control unit and the power unit. Communication errors detected between the drive control unit and the power unit. Communication errors detected between the drive control unit and the power unit. - Check the connections between the drive control unit and the power unit. Communication errors detected between the drive control unit and the power unit. - Check the connections between the drive control unit and the power unit. TempWarning TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_WRNG Excess temperature Temperature measurement from the power unit is too high Measured temperature from power unit is too high. TempSensorWarning TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_WRNG Measurement circuit temperature Problem with internal temperature measurement of the drive Problem with internal temperature measurement of the drive Problem with internal temperature measurement of the drive. - Contact your local ABB representative. Problem with internal temperature measurement of the drive. - Contact your local ABB representative. TempDifWarning TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_WRNG Excess temperature difference High temperature difference between the IGBTs of different phases. High temperature difference between the IGBTs of different phases. Check the motor cabling. Check cooling of drive module(s). High temperature difference between the IGBTs of different phases. BRResistorWarning TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_WRNG Brake resistor Brake chopper power lower than required. Brake chopper power lower than required. Brake resistor broken or not connected. -Check that a brake resistor has been connected. -Check the condition of the brake resistor. Brake resistor broken or not connected. -Check that a brake resistor has been connected. -Check the condition of the brake resistor. BUEFWarning TUCOS_BU_Events BU earth leakage Earth leakage warning detected by the branching unit: sum of all currents is exceeding the level. BUIDiffWarning TUCOS_BU_Events EVNT_SEP_AUX_WRNG BU current difference Difference check warning for currents BUUCDiffWarning TUCOS_BU_Events EVNT_SEP_AUX_WRNG BU DC link difference Branching unit difference check warning for DC link voltage BUCDDiffWarning TUCOS_BU_Events EVNT_SEP_AUX_WRNG BU commutation difference Branching unit difference check warning for CDX and CDY. LinkErrWarning TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_WRNG PU communication Communication errors detected between the drive control unit and the power unit. Communication errors detected between the drive control unit and the power unit Communication errors detected between the drive control unit and the power unit. - Check the connection between the drive control unit and the power unit. Communication errors detected between the drive control unit and the power unit. - Check the connection between the drive control unit and the power unit. Some PU communication diagnostic counter is counting => warning STSVWarning TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_WRNG PU state feedback PU state feedback PU state feedback State feedback supervision supervises the state feedback signals from the output phases and compares the signals to the actual control signals. All of the output phases are sampled invidually. State feedback supervision supervises the state feedback signals from the output phases and compares the signals to the actual control signals. All of the output phases are sampled invidually. State feedback supervision supervises the state feedback signals from the output phases and compares the signals to the actual control signals. All of the output phases are sampled invidually. CHGWarning TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_WRNG Charging feedback Charging feedback missing The charging feedback is missing. Formerly INVD BUUmainDiffWarning TUCOS_BU_Events EVNT_SEP_AUX_WRNG BU voltage difference Branching unit difference check warning for main voltage RedundantMeasurementPSWarning TUCOS_PSL2_DRIVER_Events Redundant measurement Redundant measurement Redundant measurement Redundant measurement supervision has indicated a difference in the duplicated measurements that is outside the limits. - Contact your local ABB representative. Redundant measurement supervision has indicated a difference in the duplicated measurements that is outside the limits. - Contact your local ABB representative. Redundant measurement supervision has indicated a difference in the duplicated measurements that is outside the limits. (Solar applications) OverTemp3LWarning TUCOS_PSL2_DRIVER_Events EVNT_SEP_AUX_WRNG Overtemperature hw Overtemperature hw detection (3L target specific) FlashConsumptionSpeed TUCOS_GENERAL_Events Flash erase speed exceeded ehndl_PUSAVE_warning PU Save EVNT_SEP_AUX_WRNG Data saving to power unit An error detected in saving data to power unit. An error detected in saving data to power unit. An error detected in saving data to power unit. Industial and standard drives harmonized event code is 0xA683 Power unit saving does not work properly. Replace the power unit. If saving to power unit is not necessary, the warning can be cleared by disabling the feature with parameter 96.30. EFBSerial1ErrWarning TUCOS_EFB_Events EFB comm loss The EFB has detected a comm loss. Check communications with system. EFB comm loss warning The embedded fieldbus (EFB) interface has detected a comm loss. Please check communications with master / PLC / supervisory controller. See parameters 58.07, 58.08, and 58.09 to adjust settings. The embedded fieldbus (EFB) interface has detected a comm loss. Please check communications with master / PLC / supervisory controller. See parameters 58.07, 58.08, and 58.09 to adjust settings. ehndl_SDCardWrng TUCOS_GENERAL_Events EVNT_SEP_AUX_WRNG SD card SD card SD card is not operational. Check that the SD card is properly inserted in the control unit and that it is in working condition. SD card is not operating properly (with BCU control unit only). Saving power unit diagnostic data on SD card may not be possible. SD card is not operational. DummyWarning3 TUREL_FA_STUB_Events Dummy 3 Dummy warning for testing purposes. DummyWarning2 TUREL_FA_STUB_Events Dummy 2 Dummy warning for testing purposes. DummyWarning TUREL_FA_STUB_Events Dummy 1 Dummy warning for testing purposes. ehndl_mapped_par_value_cut ParameterMap Mapped parameter value cut Mapped parameter value cut Mapped parameter value cut Check parameter scaling and format. ehndl_par_map_configuration ParameterMap Parameter map configuration Parameter map configuration Parameter map configuration Too many parameters in configuration file ehndl_APWarning1 AP_Program AP Warning 1 ehndl_APWarning2 AP_Program AP Warning 2 ehndl_APWarning3 AP_Program AP Warning 3 ehndl_APWarning4 AP_Program AP Warning 4 ehndl_APWarning5 AP_Program AP Warning 5 ehndl_APPure1 AP_Program AP Pure Event 1 ehndl_APPure2 AP_Program AP Pure Event 2 ehndl_APPure3 AP_Program AP Pure Event 3 ehndl_APPure4 AP_Program AP Pure Event 4 ehndl_APPure5 AP_Program AP Pure Event 5 STOPureEvent TUCOS_PSL2_DRIVER_Events STO event Safe torque off function is active. Safe torque off function is active Safe torque off function is active, i.e. safety circuit signal(s) connected to connector XSTO is broken during start, or while drive is stopped and parameter 31.22 STO diagnostics is set to Fault. - Check safety circuit connections. For more information, see appropriate drive hardware manual. Safe torque off function is active, i.e. safety circuit signal(s) connected to connector XSTO is broken during start, or while drive is stopped and parameter 31.22 STO diagnostics is set to Fault. - Check safety circuit connections. IDRunDone TUCTC_Events ID run done ID run has been performed successfully ID run has been performed successfully None Normal Reduced Standstill Autophasing Current measurement calibration Advanced Advanced standstill ehndl_TUCSO_fault FS_BASIC EVNT_SEP_AUX_FLT EVNT_IMMEDIATE_FLT TUCSO fault FSO subsystem fault FSO subsystem fault. FSO subsystem fault. FSO subsystem fault. ehndl_FSO_FAULTS_GEN FS_BASIC EVNT_SEP_AUX_FLT EVNT_IMMEDIATE_FLT FSO general fault FSO general fault FSO makes first a warning, then this General fault. This fault always follows certain malfunctions which the FSO module indicates by warnings. The FSO module generates a warning indication first to allow the drive to control the system to a safe state after which the drive trips (to this fault). This fault always follows certain malfunctions which the FSO module indicates by warnings. The FSO module generates a warning indication first to allow the drive to control the system to a safe state after which the drive trips (to this fault). ehndl_FSOF_StopCompleted FS_BASIC EVNT_SEP_AUX_FLT EVNT_IMMEDIATE_FLT FSO stop completed FSO stop completed FSO stop completed FSO module has completed STO, SS1 or SSE function. FSO module has completed STO, SS1 or SSE function. ehndl_FSOF_SafeSpeedLimit FS_BASIC EVNT_SEP_AUX_FLT EVNT_IMMEDIATE_FLT FSO safe speed limit FSO safe speed limit FSO safe speed limit Motor actual speed exceeded a safe speed limit of the FSO module. Motor actual speed exceeded a safe speed limit of the FSO module. ehndl_FSOF_OutOfEmeRamp FS_BASIC EVNT_SEP_AUX_FLT EVNT_IMMEDIATE_FLT FSO out of eme ramp FSO out of eme ramp FSO out of emergency ramp. Motor speed was not inside the ramp window during the SSE function. Make sure that the drive can decelerate the load using the ramp time (200.102 SAR0 ramp time to zero). Motor speed was not inside the ramp window during the SSE function. Make sure that the drive can decelerate the load using the ramp time (200.102 SAR0 ramp time to zero). ehndl_FSOF_RampCoasted FS_BASIC EVNT_SEP_AUX_FLT EVNT_IMMEDIATE_FLT FSO ramp coasted FSO ramp coasted Drive coasted the motor during ramp. Drive coasted the motor to stop instead of using the ramp. Check that the FSO module speed limit for stopping the ramp deceleration is not excessive (FSOGEN.51 Zero speed without encoder). Drive coasted the motor to stop instead of using the ramp. Check that the FSO module speed limit for stopping the ramp deceleration is not excessive (FSOGEN.51 Zero speed without encoder). ehndl_FSOF_OutOfSafeRamp FS_BASIC EVNT_IMMEDIATE_FLT FSO out of safe ramp FSO out of safe ramp Motor speed was not inside the ramp window. Motor speed was not inside the ramp window. Make sure that the drive can decelerate the load using the ramp times. Motor speed was not inside the ramp window. Make sure that the drive can decelerate the load using the ramp times. ehndl_FSOF_OutOfSDI FS_FA EVNT_IMMEDIATE_FLT FSO out of SDI FSO out of SDI. FSO out of SDI. Motor was not rotating to the allowed direction. Motor was not rotating to the allowed direction. ehndl_FSOF_POUS_premature FS_BASIC EVNT_SEP_AUX_FLT EVNT_IMMEDIATE_FLT FSO premature POUS FSO premature POUS POUS was requested while drive was still on. POUS was requested while drive was still modulating. POUS is supposed to be activated when drive is stopped. POUS was requested while drive was still modulating. POUS is supposed to be activated when drive is stopped. ehndl_FSOF_Undef FS_BASIC EVNT_IMMEDIATE_FLT FSO undefined fault FSO undefined fault FSO undefined fault FSO new version, undefined fault in Drive event system. Contact ABB. FSO new version, undefined fault in Drive event system. Contact ABB. ehndl_FSOF_passivated FS_FA EVNT_IMMEDIATE_FLT FSO passivated FSO passivated FSO module is passivated due safetybus problems ehndl_FSO_Warnings FS_BASIC EVNT_SEP_AUX_WRNG FSO general warnings FSO general warnings. FSO general warnings. FSO general warnings. Mainly for some unrisky situations, like transition to configuration mode. See aux codes for details. FSO general warnings. Mainly for some unrisky situations, like transition to configuration mode. See aux for details. ehndl_FSO_WARNDF_INT FS_BASIC EVNT_SEP_AUX_WRNG FSO internal fault FSO internal fault. Boot the module once, see the Aux code for more details. Internal fault in the FSO module. Boot the module once, if the problem is still there, replace the FSO module. Contact your local ABB representative. See the Aux code for more details. Internal fault in the FSO module. Boot the module once, if the problem is still there, replace the FSO module. Contact your local ABB representative. See the Aux code for more details. ehndl_FSO_WARNDF_IO FS_BASIC EVNT_SEP_AUX_WRNG FSO IO fault FSO IO fault. Problems in the I/O cabling FSO IO fault. Check the FSO I/O cabling. See the Aux code for more details. FSO IO fault. Check the FSO I/O cabling. See the Aux code for more details. ehndl_FSO_WARNDF_STO FS_BASIC EVNT_SEP_AUX_WRNG FSO STO fault FSO STO fault. Problems in the STO cabling or inside the drive. Check the FSO STO cabling. Problems in the STO cabling or inside the drive. FSO STO fault. Problems in the STO cabling or inside the drive. Check the FSO STO cabling. FSO STO fault. ehndl_FSO_WARNDF_STOREQ FS_BASIC EVNT_SEP_AUX_WRNG FSO STO request FSO STO request. External STO request. FSO STO request. FSO module received an external STO request eitehr from IO or safebus. FSO STO request. FSO module received an external STO request eitehr from IO or safebus. ehndl_FSO_WARNDF_COMM FS_BASIC EVNT_SEP_AUX_WRNG FSO communication fault FSO communication fault. Check the data cable. FSO has detected a communication fault. All the communications goes through the data cable between FSO and Drive, check the connection. FSO has detected a communication fault. All the communications goes through the data cable between FSO and Drive, check the connection. ehndl_FSO_WARNDF_SBUS FS_BASIC EVNT_SEP_AUX_WRNG FSO safetybus fault FSO safetybus fault. Something wrong with the safetybus. FSO safetybus fault. Something wrong with the safetybus. See aux codes for more details. FSO safetybus fault. Something wrong with the safetybus. See aux codes for more details. ehndl_FSO_WARNDF_CONF FS_BASIC EVNT_SEP_AUX_WRNG FSO configuration fault FSO configuration fault. Check the safety module parameter settings. FSO configuration fault. Check the safety module parameter settings. Settings can be changed only with Composer pro tool. FSO configuration fault. Check the safety module parameter settings. Settings can be changed only with Composer pro tool. ehndl_FSO_SafeEnc_Fault FS_FA FSO safety encoder fault Safety encoder fault Safety encoder fault Safety encoder fault, see aux codes for details Safety encoder fault, see aux codes for details ehndl_FSO_WARNDF_ENCLESS FS_BASIC EVNT_SEP_AUX_WRNG FSO encoderless fault FSO encoderless speed estimation fault. Speed estimate is too high FSO encoderless speed estimation fault. • Check the behavior of the driven load compared with the drive control parameter settings. • Check suitability of the drive train and the motor. • Adapt control parameters if gear play or torsional rigidity causes problems. FSO encoderless speed estimation fault. • Check the behavior of the driven load compared with the drive control parameter settings. • Check suitability of the drive train and the motor. • Adapt control parameters if gear play or torsional rigidity causes problems. ehndl_FSO_WARNDF_TEMP FS_BASIC EVNT_SEP_AUX_WRNG FSO temperature fault FSO over temperature FSO module temperature is excessive. FSO over temperature. • Check ambient conditions. Boot the FSO module (power switch off/on). • Replace the FSO-11 module. Contact your local ABB representative. FSO over temperature. • Check ambient conditions. Boot the FSO module (power switch off/on). • Replace the FSO-11 module. Contact your local ABB representative. ehndl_FSOW_Undef FS_BASIC FSO undefined warning FSO undefined warning New FSO, undefined warning. FSO new version, undefined warning in Drive event system. FSO new version, undefined warning in Drive event system. ehndl_FSOW_StopCompleted FS_BASIC EVNT_SEP_AUX_WRNG FSO stop completed FSO stop completed FSO stop completed. FSO module has completed STO, SS1 or SSE function. FSO module has completed STO, SS1 or SSE function. ehndl_FSOW_SafeSpeedLimit FS_BASIC EVNT_SEP_AUX_WRNG FSO safe speed limit FSO safe speed limit FSO safe speed limit Motor actual speed exceeded a safe speed limit of the FSO module. Motor actual speed exceeded a safe speed limit of the FSO module. ehndl_FSOW_OutOfEmeRamp FS_BASIC EVNT_SEP_AUX_WRNG FSO out of eme ramp FSO out of eme ramp Motor speed was not inside the eme ramp. Motor speed was not inside the ramp window during the SSE function. Make sure that the drive can decelerate the load using the ramp time (200.102 SAR0 ramp time to zero). Motor speed was not inside the ramp window during the SSE function. Make sure that the drive can decelerate the load using the ramp time (200.102 SAR0 ramp time to zero). ehndl_FSOW_RampCoasted FS_BASIC EVNT_SEP_AUX_WRNG FSO ramp coasted FSO ramp coasted Drive coasted instead of ramping. Drive coasted the motor to stop instead of using the ramp. Check that the FSO module speed limit for stopping the ramp deceleration is not excessive (FSOGEN.51 Zero speed without encoder). Drive coasted the motor to stop instead of using the ramp. Check that the FSO module speed limit for stopping the ramp deceleration is not excessive (FSOGEN.51 Zero speed without encoder). ehndl_FSOW_OutOfSafeRamp FS_BASIC FSO out of safe ramp FSO out of safe ramp Motor speed was not inside the ramp window. Motor speed was not inside the ramp window. Make sure that the drive can decelerate the load using the ramp times. Motor speed was not inside the ramp window. Make sure that the drive can decelerate the load using the ramp times. ehndl_FSOW_OutOfSDI FS_FA FSO out of SDI FSO out of SDI. FSO out of SDI. Motor was not rotating to the allowed direction. Motor was not rotating to the allowed direction. ehndl_FSOW_POUS_Request FS_BASIC EVNT_SEP_AUX_WRNG FSO POUS request FSO POUS request FSO POUS request and activation. Prevention Of Unexpected Startup was requested via inputs or safebus, and it was activated. Prevention Of Unexpected Startup was requested via inputs or safebus, and it was activated. ehndl_FSOW_passivated FS_FA FSO passivated FSO passivated FSO module is passivated due safetybus problems ehndl_FSOW_STO_Request FS_BASIC EVNT_SEP_AUX_WRNG FSO STO request FSO STO request FSO STO external request FSO module received an external STO request from the inputs or the safebus. FSO module received an external STO request from the inputs or the safebus. ehndl_FSOW_SSE_Request FS_BASIC EVNT_SEP_AUX_WRNG FSO SSE request FSO SSE request FSO SSE external request FSO module received an external SSE request from the inputs or the safebus. FSO module received an external SSE request from the inputs or the safebus. ehndl_FSOW_SS1_Request FS_BASIC EVNT_SEP_AUX_WRNG FSO SS1 request FSO SS1 request FSO SS1 external request FSO module received an external SS1 request from the inputs or the safebus. FSO module received an external SS1 request from the inputs or the safebus. ehndl_FSOW_SLS1hit FS_BASIC EVNT_SEP_AUX_WRNG FSO SLS1 hit FSO SLS1 hit FSO SLS1 limit hit FSO module detected a SLS1 speed limit violation. FSO module detected a SLS1 speed limit violation. ehndl_FSOW_SLS2hit FS_BASIC EVNT_SEP_AUX_WRNG FSO SLS2 hit FSO SLS2 hit FSO SLS2 limit hit FSO module detected a SLS2 speed limit violation. FSO module detected a SLS2 speed limit violation. ehndl_FSOW_SLS3hit FS_BASIC EVNT_SEP_AUX_WRNG FSO SLS3 hit FSO SLS3 hit FSO SLS3 limit hit FSO module detected a SLS3 speed limit violation. FSO module detected a SLS3 speed limit violation. ehndl_FSOW_SLS4hit FS_BASIC EVNT_SEP_AUX_WRNG FSO SLS4 hit FSO SLS4 hit FSO SLS4 limit hit FSO module detected a SLS4 speed limit violation. FSO module detected a SLS4 speed limit violation. ehndl_FSOW_SMShit FS_BASIC EVNT_SEP_AUX_WRNG FSO SMS hit FSO SMS hit FSO SMS limit hit FSO module detected a SMS speed limit violation. FSO module detected a SMS speed limit violation. ehndl_FSOW_SAR0hit FS_BASIC EVNT_SEP_AUX_WRNG FSO SAR0 hit FSO SAR0 hit FSO SAR0 limit violation. FSO module detected a SAR0 limit violation. Make sure that the drive can decelerate the load using the ramp time (200.102 SAR0 ramp time to zero). FSO module detected a SAR0 limit violation. Make sure that the drive can decelerate the load using the ramp time (200.102 SAR0 ramp time to zero). ehndl_FSOW_SAR1hit FS_BASIC EVNT_SEP_AUX_WRNG FSO SAR1 hit FSO SAR1 hit FSO SAR1 limit violation. FSO module detected a SAR1 limit violation. Make sure that the drive can decelerate the load using the ramp time (200.112 SAR1 ramp time to zero). FSO module detected a SAR1 limit violation. Make sure that the drive can decelerate the load using the ramp time (200.112 SAR1 ramp time to zero). ehndl_FSOW_OutOfSDIp FS_FA FSO SDIp hit FSO SDI-p hit FSO SDI-p hit Motor was not rotating to the positive direction. Motor was not rotating to the positive direction. ehndl_FSOW_OutOfSDIn FS_FA FSO SDIn hit FSO SDI-n hit FSO SDI-n hit Motor was not rotating to the negative direction. Motor was not rotating to the negative direction. ehndl_FSOW_RampTimeHit FS_BASIC EVNT_SEP_AUX_WRNG FSO ramp time hit FSO time monitored ramp hit FSO time monitored ramp hit FSO module detected a violation of a time monitored ramp. Make sure that the drive can decelerate the load within the time defined for ramp time monitoring. FSO module detected a violation of a time monitored ramp. Make sure that the drive can decelerate the load within the time defined for ramp time monitoring. • Check the drive ramp time settings. • Check that the drive can in fact accomplish the deceleration along the ramp defined. Make sure that the limit for ramp time monitoring of the FSO module exceeds the actual drive ramp time. The parameter vary depending on the safety function. For the SS1 function it is SS1.14 SS1 delay for STO. ehndl_FSOW_ZeroSpdHit FS_BASIC EVNT_SEP_AUX_WRNG FSO zero spd hit FSO zero speed rush Drive speed rushed during zero speed delay. Drive speed rushed during zero speed delay. Drive speed rushed during zero speed delay. ehndl_FSOW_SpdSynFail FS_BASIC FSO speed sync fail FSO speed sync fail FSO detected a difference between the monitored motor speeds. FSO module detected a difference between the two monitored motor speed values (200.01FSO speed ch1 and 200.02 FSO speed ch2). Restart the drive and FSO module. FSO module detected a difference between the two monitored motor speed values (200.01 FSO speed ch1 and 200.02 FSO speed ch2). Restart the drive and FSO module. ehndl_FSOW_varSLShit FS_BASIC FSO varSLS hit FSO variable SLS hit FSO variable SLS limit hit. FSO module detected a variable SLS speed limit violation. FSO module detected a variable SLS speed limit violation. ehndl_FSOW_passivation FS_FA FSO safebus passivation FSO passivation FSO safe bus passivation due communication problems PowerUp TUCOS_GENERAL_Events Power up Diagnostic information about the last boot cycle The drive has been powered up. Boot Type: Undefined No information about boot type available Boot Type: Cold boot Drive was powered-on Boot Type: Warm boot - OK Drive was restarted expectedly Boot Type: Warm boot - ERR Drive had critical error and restart was needed. Information should be saved in SSW internal diagnostics ehndl_SSW_InternalDiagnostics TUCOS_GENERAL_Events SSW internal diagnostics Diagnostic event from the system SW. System SW diagnostics System SW diagnostics has recorded an exceptional event during normal execution of the system SW. The aux code of the event contains more information for ABB Drives. System SW diagnostics has recorded an exceptional event during normal execution of the system SW. The aux code of the event contains more information for ABB Drives. System SW has noticed an exception in execution of the software. The aux code of the event contains more information. Program counter value Sub event nr 1. Report to ABB Drives. Value of the program counter. Aux. code: 0x1xxxxxxx xxxxxxx = value of the program counter Stack pointer value Sub event nr 2. Report to ABB Drives. Value of the stack pointer. Aux. code: 0x2xxxxxxx xxxxxxx = value of the stack pointer Packed crash data Sub event nr 3. Report to ABB Drives. Crash details: Aux. code: 0x3000xyzz x - interrupt nesting level y - crash count zz - exception number. ehndl_PowerUnitLogicUpdateEvent TUCOS_Power_Unit Power unit's logic update transaction An event generated during download of the logic configuration file to the PU. Check the aux code for more information. Power unit's logic update event An event generated during download of the logic configuration file to the PU. Check the aux code for more information. An event generated during download of the logic configuration file to the PU. Check the aux code for more information. An event generated during download of the logic configuration file to the PU. Check the aux code for more information. Download starts Download successful Download failed ehndl_FSO_Events FS_BASIC FSO general event FSO general event FSO general event FSO general event, see aux codes for details. FSO general event, see aux codes for details. ehndl_FSO_DIAGS FS_BASIC FSO diagnostics FSO boottime diags. Only for manufacturing tests, TUCSO (FSO subsystem) will forget these. ehndl_FSOE_Undef FS_BASIC FSO undefined event FSO undefined event FSO undefined event. FSO new version, undefined event in Drive event system. FSO new version, undefined event in Drive event system. ehndl_FSOE_FSECh1Diag FS_FA FSE-31 ch1 diagnostics FSE-31 ch1 diag FSE-31 ch1 diag FSE-31 channel 1 diagnostics data, see aux codes for details. FSE-31 channel 1 diagnostics data, see aux codes for details. ehndl_FSOE_FSECh2Diag FS_FA FSE-31 ch2 diagnostics FSE-31 ch2 diag FSE-31 ch2 diag FSE-31 channel 2 diagnostics data, see aux codes for details. FSE-31 channel 2 diagnostics data, see aux codes for details. ehndl_FSOE_StopCompleted FS_BASIC FSO stop completed FSO stop completed FSO stop completed FSO module has completed STO, SS1 or SSE function. FSO module has completed STO, SS1 or SSE function. ehndl_FSOE_SafeSpeedLimit FS_BASIC FSO safe speed limit FSO safe speed limit FSO safe speed limit Motor actual speed exceeded a safe speed limit of the FSO module. FSO safe speed limit. Motor actual speed exceeded a safe speed limit of the FSO module. ehndl_FSOE_OutOfEmeRamp FS_BASIC FSO out of eme ramp FSO out of eme ramp Motor speed was not inside the ramp window. Motor speed was not inside the ramp window during the SSE function. Make sure that the drive can decelerate the load using the ramp times. (200.102 SAR0 ramp time to zero) Motor speed was not inside the ramp window during the SSE function. Make sure that the drive can decelerate the load using the ramp times. (200.102 SAR0 ramp time to zero) ehndl_FSOE_RampCoasted FS_BASIC FSO ramp coasted FSO ramp coasted Drive coasted the motor to stop during the ramp. Drive coasted the motor to stop instead of using the ramp. Check that the FSO module zero speed limit for the deceleration ramp is not excessive (FSOGEN.51 Zero speed without encoder). Drive coasted the motor to stop instead of using the ramp. Check that the FSO module zero speed limit for the deceleration ramp is not excessive (FSOGEN.51 Zero speed without encoder). ehndl_FSOE_OutOfSafeRamp FS_BASIC FSO out of safe ramp FSO out of safe ramp Motor speed was not inside the ramp window. Motor speed was not inside the ramp window. Make sure that the drive can decelerate the load using the ramp times. Motor speed was not inside the ramp window. Make sure that the drive can decelerate the load using the ramp times. ehndl_FSOE_OutOfSDI FS_FA FSO out of SDI FSO out of SDI. FSO out of SDI. Motor was not rotating to the allowed direction. Motor was not rotating to the allowed direction. ehndl_FSOE_passivated FS_FA FSO passivated FSO passivated FSO module is passivated due safetybus problems ehndl_FSOE_STO_request FS_BASIC FSO STO request FSO STO request External STO request. FSO module received an external STO request. FSO module received an external STO request. ehndl_FSOE_SSE_Request FS_BASIC FSO SSE request FSO SSE request External SSE request FSO module received an external SSE request. FSO module received an external SSE request. ehndl_FSOE_SS1_Request FS_BASIC FSO SS1 request FSO SS1 request External SS1 request. FSO module received an external SS1 request. FSO module received an external SS1 request. ehndl_FSOE_SLS1hit FS_BASIC FSO SLS1 hit FSO SLS1 hit FSO SLS1 hit FSO module detected a SLS1 speed limit violation. FSO module detected a SLS1 speed limit violation. ehndl_FSOE_SLS2hit FS_BASIC FSO SLS2 hit FSO SLS2 hit FSO SLS2 hit FSO module detected a SLS2 speed limit violation. FSO module detected a SLS2 speed limit violation. ehndl_FSOE_SLS3hit FS_BASIC FSO SLS3 hit FSO SLS3 hit FSO SLS3 hit FSO module detected a SLS3 speed limit violation. FSO module detected a SLS3 speed limit violation. ehndl_FSOE_SLS4hit FS_BASIC FSO SLS4 hit FSO SLS4 hit FSO SLS4 hit FSO module detected a SLS4 speed limit violation. FSO module detected a SLS4 speed limit violation. ehndl_FSOE_SMShit FS_BASIC FSO SMS hit FSO SMS hit FSO SMS hit FSO module detected a SMS speed limit violation. FSO module detected a SMS speed limit violation. ehndl_FSOE_SAR0hit FS_BASIC FSO SAR0 hit FSO SAR0 hit FSO SAR0 limit violation. FSO module detected a SAR0 limit violation.Make sure that the drive can decelerate the load using the ramp time (200.102 SAR0 ramp time to zero). FSO module detected a SAR0 limit violation.Make sure that the drive can decelerate the load using the ramp time (200.102 SAR0 ramp time to zero). ehndl_FSOE_SAR1hit FS_BASIC FSO SAR1 hit FSO SAR1 hit FSO SAR1 limit violation. FSO module detected a SAR1 limit violation. Make sure that the drive can decelerate the load using the ramp time (200.112 SAR1 ramp time to zero). FSO module detected a SAR1 limit violation. Make sure that the drive can decelerate the load using the ramp time (200.112 SAR1 ramp time to zero). ehndl_FSOE_OutOfSDIp FS_FA FSO SDIp hit FSO SDI-p hit FSO SDI-p hit Motor was not rotating to the positive direction. Motor was not rotating to the positive direction. ehndl_FSOE_OutOfSDIn FS_FA FSO SDIn hit FSO SDI-n hit FSO SDI-n hit Motor was not rotating to the negative direction. Motor was not rotating to the negative direction. ehndl_FSOE_RampTimeHit FS_BASIC FSO ramp time hit FSO time monitored ramp hit FSO time monitored ramp hit FSO module detected a violation of a time monitored ramp. Make sure that the drive can decelerate the load within the time defined for ramp time monitoring. FSO module detected a violation of a time monitored ramp. Make sure that the drive can decelerate the load within the time defined for ramp time monitoring. • Check the drive ramp time settings. • Check that the drive can in fact accomplish the deceleration along the ramp defined. Make sure that the limit for ramp time monitoring of the FSO module exceeds the actual drive ramp time. The parameter vary depending on the safety function. For the SS1 function it is SS1.14 SS1 delay for STO. ehndl_FSOE_ZeroSpdHit FS_BASIC FSO zero spd hit FSO zero speed rush. FSO zero speed rush. Drive speed was rushing during zero speed delay. Drive speed was rushing during zero speed delay. ehndl_FSOE_SpdSynFail FS_BASIC FSO speed sync fail FSO speed sync fail Difference between the two monitored motor speeds. FSO module detected a difference between the two monitored motor speed values (200.01 FSO speed ch1 and 200.01 FSO speed ch2). Restart the drive and FSO module. FSO module detected a difference between the two monitored motor speed values (200.01 FSO speed ch1 and 200.02 FSO speed ch2). Restart the drive and FSO module. ehndl_FSOE_varSLShit FS_BASIC FSO varSLS hit FSO variable SLS hit FSO variable SLS speed limit violation. FSO module detected a variable SLS speed limit violation. FSO module detected a variable SLS speed limit violation. ehndl_FSOE_passivation FS_FA FSO safebus passivation FSO passivation FSO safe bus passivation due communication problems LanguageToolNotice PROPAR ehndl_CommunicationBreak15s SSW Used to indicate that heartbeat will be lost for maximum time of 15 seconds and that tool/panel should not disconnect drive completely during that time. ParsChangedToolNotice PROPAR Notice for the tool channels that the parameter system has changed. ehndl_AccessLevelNotice PROPAR Given when any access level is selected and new menu visibilities are created. ehndl_ToolNotice_FLT Channel_logs_notice Notice for tool channel: New items have been written to fault log. Based on this notice the tool channel can refresh the active fault list and/or the fault log. ehndl_FB1Notice_FLT Channel_logs_notice Notice for field bus 1 channel: New items have been written to fault log. Based on this notice the FB1 channel can refresh the active fault list and/or the fault log. ehndl_FB2Notice_FLT Channel_logs_notice Notice for field bus 2 channel: New items have been written to fault log. Based on this notice the FB2 channel can refresh the active fault list and/or the fault log. ehndl_ToolNotice_WRNG Channel_logs_notice Notice for tool channel: New items have been written to event log. Based on this notice the tool channel can refresh the active warning list and/or the event log. ehndl_FB1Notice_WRNG Channel_logs_notice Notice for field bus 1 channel: New items have been written to event log. Based on this notice the FB1 channel can refresh the active warning list and/or the event log. ehndl_FB2Notice_WRNG Channel_logs_notice Notice for field bus 2 channel: New items have been written to event log. Based on this notice the FB2 channel can refresh the active warning list and/or the event log. DummyNotice TUREL_FA_STUB_Events Dummy notice for testing purposes. ehndl_FSx_undefined_fault FS_BASIC EVNT_IMMEDIATE_FLT FSx undefined fault FSx undefined fault FSx undefined fault FSx new version, undefined fault in Drive event system. Contact ABB. FSx undefined fault is not yet defined inside the drive. Gather the AUX codes from this fault and contact ABB. ehndl_FSx_internal_fault FS_BASIC EVNT_IMMEDIATE_FLT FSx internal fault FSx internal fault; change FSx and send it back to factory FSx internal fault Replace FSx and send the faulty one back to factory. There is no way to fix the FSx. FSx internal faults, like CPU or memory or peripherals: No possibility to fix. WSB_STATE_ERR WSB_PSOUT_ERR WSB_STOP_ERR WSB_CHKIN_ERR WSB_SYNCO_ERR WSB_CHKIN_TIMEOUT WSB_CHKIN_INVERS WOS_TRS_INV WOS_TSP_ERR WOS_TSP_SEM WOS_TSP_INV WOS_MQC_OS WOS_CPUL_ERR WOS_CPUL_NULL WOS_TRS_ERR WOS_MQC_INV_TASK WOS_MQC_INV_BUF HAL_DEV_STOCB_ERR CTRL_MAIN_HIM_INV_MSG_ID CTRL_WDG_HIM_MSG_NULL_PTR CTRL_WDG_HIM_INV_MSG_ID CTRL_CLOCK_BTSRM_NULL_PTR CTRL_MAIN_RCT_INV_EVENT CTRL_CLOCK_HIM_MSG_NULL_PTR CTRL_CLOCK_HIM_INV_MSG_ID CTRL_MAIN_HIM_MSG_NULL_PTR WOS_EVPS_INV CTRL_CLOCK_GWTI_INVALID_ARG BOOT_MAIN_SWITCH_DEFAULT_BRANCH HAL_HET_RESERVED E_FLT_FSx_INTERNAL_NO_ERR BOOT_MAIN_PM_INV_EVENT COMM_NONSAFE_INV_ERR_CODE HAL_TEMPR_NULL WOS_TC_OS WOS_TC_INV_FUNC WOS_TC_INV_STACK WOS_TC_INV_STACKSZ WOS_TC_INV_OUTP WOS_TC_PRI WOS_TC_TOO_MANY WOS_TC_ERR WOS_TID_INV_OUTP WOS_TID_NA DIAG_CPU_L2L3 WOS_NESTED_SCH DIAG_TEST_EWT_INV_STATE DIAG_TEST_SWT_INV_STATE DIAG_TEST_VOLTAGE_INV_MODE DIAG_TEST_WDG_INV_STATE DIAG_MAIN_RTS_INV_STK_SIZE DIAG_TEST_VOLTAGE_INV_STATE DIAG_MAIN_RBT2_INV_MODE DIAG_MAIN_HTM_TMON_TIMEOUT DIAG_TEST_WDG_INV_MODE DIAG_MAIN_RBT3_INV_MODE DIAG_CPU_FEE HAL_DEV_WRI_INV_LN WOS_CONV_MS_INV_OUTP WSB_PSIN_INV WSB_START_ERR WSB_CONF_RESP_FAIL WOS_MQPO_INV WSB_CONF_CRC WSB_CONF_ADDR WSB_CONF_ERR SAFETY_STO_INV_CONDITION WSB_INIT_ERR WSB_PSIN_LEN WSB_CONF_SIL WSB_CONF_WAIT_PARS HAL_WDG_RESET_LOW_HWWDG SAFETY_STO_INV_SW_MODE HAL_WDG_RESET_LOW_TRIG HAL_DEV_RDI_NULL HAL_WDG_RESET_HIGH_HWWDG HAL_WDG_RESET_HIGH_POWERGOOD HAL_WDG_RESET_HIGH_TRIG HAL_WDG_RESET_HIGH_NERROR_PIN HAL_INIT_ERR SAFETY_TRIG_STATE_LOW HAL_NULL_CB HAL_NULL_ARG WOS_LOCKED_SCH HAL_DEV_STO_TEST_NA HAL_DEV_STO_DELAYED WSB_PSIN_FULL WOS_MQC_INV_OUTP WSB_PLIN_ERR SAFETY_STO_INV_LOCK COMM_NULL_POINTER HAL_HET1_OVERFLOW HAL_HET1_NULL_IRQ HAL_WDTS_BUSY HAL_WDTP_START HAL_TIMER_INV HAL_WDTS_NULL HAL_DEV_ROII_INV_ARG HAL_TEMP_ADC_FAILURE HAL_WDTR_STOP HAL_DEV_ROII_NULL DIAG_MAIN_DTI_INV_STATUS DIAG_MAIN_DTI_TEST_TIMEOUT SAFETY_NULL_PTR CTRL_MAIN_HCM_CU_MSG_NOT_PACKED CTRL_MAIN_USFS_INV_FUNC CTRL_MAIN_USM_INV_MODE CTRL_WDG_STSRM_INVALID_MSG_TYPE DIAG_MAIN_DTI_INV_TEST_ID DIAG_MAIN_HIDM_INV_MSG_ID DIAG_MAIN_RDT_INV_EVENT DIAG_NULL_PTR HAL_WDG_RESET_LOW_POWERGOOD HAL_DEV_STO_DIAG CTRL_WDG_STSRM_NULL_PTR DIAG_MAIN_HATM_TOO_BIG_DRIFT DIAG_HW_WDG_BITE DIAG_POWERGOOD_BITE DIAG_MAIN_RTS_NO_SLOTS HAL_TIMER_ERROR DIAG_CPU_SRAM DIAG_CPU_FLASH DIAG_CPU_CCM DIAG_CPU_PMM SAFETY_STO_INV_STATE SAFETY_HID_STO_TEST_TO SAFETY_INVALID_ARG SAFETY_SA_INV_PARAM SAFETY_HDSFR_INV_PARAMS SAFETY_HASFR_INV_SOURCE SAFETY_HASFR_INV_FUNC SCOMM_NULL_PTR SCOMM_SHIM_UNKNOWN_MSG SAFETY_RBST_INV_SW_MODE BOOT_START_DIAG_FAILED SCOMM_PI_LENGTH_ERR SCOMM_PASS_PARAMS_RECV SCOMM_INV_EVENT BOOT_MAIN_HCM_CU_MSG_NOT_PACKED SCOMM_PASS_PROFILE_LEN WSB_INIT_NULL WSB_PSIN_NULL WSB_CONF_LEN SCOMM_PI_UNKNOWN_TYPE WOS_MQPL_INV WSB_INIT_PROF HAL_TIMER_TOO_LONG_DLY HAL_TIMER_BUSY SAFETY_INV_EVENT SAFETY_SHIM_UNKNOWN_MSG HAL_DEV_WRI_INV_ST WOS_CONV_MS_OVF WOS_MEC_INV HAL_DEV_STOCB_NULL HAL_HET_OFFSET WOS_EVPS_ERR WOS_AP2OP_INV_OUTP WOS_AP2OP_INV_PRIO COMM_NONSAFE_INV_LEN COMM_NONSAFE_INV_TYPE CTRL_TASK_REG_INVALID_PERIOD CTRL_TASK_REG_INVALID_ID CTRL_TASK_REG_INVALID_INIT_VAL CTRL_TASK_REG_INVALID_SHIFT CTRL_WDG_RHI_INV_TASK CTRL_CLOCK_ICT_INVALID_TABLE CTRL_CLOCK_RCT_INV_EVENT CTRL_WDG_RSWT_INV_EVENT HAL_DEV_STO_BOOT HAL_WDG_RESET_LOW_NERROR_PIN WOS_MQGC_INV WOS_MQPO_ERR WOS_EVPE_INV_OUTP WOS_MQGC_NULL WOS_EVPE_TIMEOUT WOS_EVPE_ISR WOS_EVPL_INV_OUTP WOS_EVPE_ERR WOS_EVPL_NA WOS_EVPL_ISR HAL_DEV_STO_INV_OP ERR_UNKNOWN E_FLT_FSx_INTERNAL_LAST DIAG_MAIN_GTEC_HW_COMPATIBILITY_TEST DIAG_MAIN_GTEC_INV_ID DIAG_MAIN_GTEC_VOLT_MON_TEST DIAG_MAIN_GTEC_SW_COMPATIBILITY_TEST DIAG_MAIN_GTEC_CPU_FLASH_TEST DIAG_MAIN_GTEC_WATCHDOG_TEST DIAG_MAIN_CS_CHECK_FAILED DIAG_MAIN_GTEC_CPU_STARTUP DIAG_MAIN_HBT_INV_TEST_MODE DIAG_MAIN_FS_FILL_FAILED COMMON_NULL_ADDRESS BOOT_MAIN_HIM_INV_MSG_ID COMM_NONSAFE_INV_NULL HAL_DEV_STO_SAFE WOS_MQPL_ERR WSB_CNM_EXCHANGE WOS_MQPL_ISR WOS_MQPL_NA WSB_PSIN_IGNORE WOS_MQPL_NULL WSB_CHKIN_NULL WOS_MQC_TOO_MANY WSB_CHKIN_CRC WSB_CHKIN_PASS WOS_MQPO_INV_MSG WOS_MQPO_FULL DIAG_GOLDEN_REGISTER_SET_FAIL DIAG_GOLDEN_CRC_SET_FAIL DIAG_REGISTERS DIAG_CRCS DIAG_ESM_OUTPUT DIAG_CPU_MPU DIAG_CPU_DCC DIAG_CPU_VIM HAL_UNKNOWN_INT DIAG_ESM_FAILURE ehndl_FSx_STO_diagnostics_fault FS_BASIC EVNT_IMMEDIATE_FLT FSx STO diagnostics fault FSx STO fault; check STO cabling FSX STO fault There is something wrong with STO cabling or inside the Drive. FSX STO fault; there is something wrong with STO cabling or inside the Drive. SAFETY_STO_DEACT_FAILED E_FLT_FSx_STO_DIAGNOSTICS_NO_ERR SAFETY_STO_INV_STO_HI_STATE SAFETY_STO_PULSE_FAILED SAFETY_SLT_INV_LO_FB_STATE SAFETY_STO_HI_GONE_LOW HAL_INIT_STO_STATE SAFETY_STO_INV_FEEDBACK E_FLT_FSx_STO_DIAGNOSTICS_LAST ehndl_FSx_temperature_fault FS_BASIC EVNT_IMMEDIATE_FLT FSx temperature fault FSx temperature FSx temperature FSX temperature fault, mainly over temperature FSX temperature fault, mainly over temperature DIAG_MAIN_GTEC_TEMP_TEST E_FLT_FSx_TEMPERATURE_NO_ERR DIAG_MAIN_HTM_TMON_S1_LIMIT DIAG_MAIN_HTM_TMON_DEVIATION DIAG_MAIN_HTM_TMON_S2_LIMIT E_FLT_FSx_TEMPERATURE_LAST ehndl_FSx_configuration_fault FS_BASIC EVNT_IMMEDIATE_FLT FSx configuration fault FSX configuration fault; check configuration FSX configuration fault FSX configuration fault; check configuration FSX configuration is not valid E_FLT_FSx_CONFIGURATION_NO_ERR E_FLT_FSx_CONFIGURATION_LAST ehndl_FSx_communication_fault FS_BASIC EVNT_IMMEDIATE_FLT FSx communication fault FSX communication fault; FSX-CU communication fault FSX communication fault. FSX communication fault; FSX-CU communication fault. Check all connections. See AUX code for more details. FSX communication fault; FSX-CU communication fault. Check all connections. See AUX code for more details. WSB_HARD_ERR E_FLT_FSx_COMMUNICATION_NO_ERR E_FLT_FSx_COMMUNICATION_LAST ehndl_FSx_safety_ramp_fault FS_BASIC EVNT_IMMEDIATE_FLT FSx safety ramp fault Safety ramp did not finish in predictable way FS safety ramp fault Safety ramp did not finish in predictable way FS safety ramp fault: Safety ramp did not finish in predictable way SS1T_TIMELIMIT E_FLT_FSx_SAFETY_RAMP_NO_ERR E_FLT_FSx_SAFETY_RAMP_LAST ehndl_FSx_undefined_warning FS_BASIC FSx undefined warning FSx undefined warning New FSx, undefined warning. FSx new version, undefined warning in Drive event system. FSx undefined warning is not yet defined inside the drive. Gather the aux codes from this warning and contact ABB. ehndl_FSx_safety_bus_warning FS_BASIC FSx safety bus warning PSAFE_FPRAM_DEV_SPECIFIC PSAFE_FPRAM_CRC1_ERROR PSAFE_FPRAM_RESTORE_IPAR_WDG_TIME PSAFE_FPRAM_SAVE_IPAR_WDG_TIME PSAFE_FPRAM_GRANDE_ERROR PSAFE_FPRAM_IPAR_CRC_ERROR PSAFE_PASS_CRC_FAILURE PSAFE_PASS_NEW_FPARAMS PSAFE_PASS_BY_PLC PSAFE_PASS_WD_TIMEOUT PSAFE_FPRAM_DEST_ADDR_MISMATCH E_WRN_FSx_SAFETY_BUS_NO_ERR PSAFE_FPRAM_SOURCE_ADDR_MISMATCH PSAFE_FPRAM_DEST_ADDR_VALIDITY PSAFE_FPRAM_WD_VALUE_ERROR PSAFE_FPRAM_SOURCE_ADDR_VALIDITY PSAFE_FPRAM_FCRCLENGTH_ERROR PSAFE_FPRAM_SIL_REQ_TOO_HIGH PSAFE_FPRAM_BLOCKID_ERROR PSAFE_FPRAM_VERSION_ERROR E_WRN_FSx_SAFETY_BUS_LAST ehndl_FSx_undefined_event FS_BASIC FSx undefined event FSx undefined event. FSx new version, undefined event in Drive event system. FSx new version, undefined event in Drive event system. ehndl_FSx_diagnostics FS_BASIC FSx diagnostics FSx diag FSx diag FSx diagnostics data, see aux codes for details. FSx diagnostics data, see aux codes for details. CPU start up tests (combined) CPU start up tests (combined) SW image CRC test SW image CRC test Own temperature test Own temperature test External HW watchdog test External HW watchdog test 3V3 and 1V2 voltage test 3V3 and 1V2 voltage test HW compatibility test HW compatibility test STO output 1 test STO output 1 test STO output 2 test STO output 2 test CPU FEE CPU FEE CPU SRAM CPU SRAM CPU FLASH CPU FLASH CPU CCM CPU CCM CPU PMM CPU PMM CPU L2L3 CPU L2L3 CPU VIM CPU VIM CPU DCC CPU DCC CPU MPU CPU MPU ESM OUTPUT ESM OUTPUT CRCS CRCS REGISTERS REGISTERS